Product

Ingersoll Rand 49164395 Air Filter Element | Donaldson FPG10 RadialSeal

Ingersoll Rand 49164395 air filter element built to Donaldson FPG10 two-stage RadialSeal specification. 208 mm OD x 106 mm ID x 409 mm length, 99.9% filtration efficiency to ISO 5011, tangential pre-cleaner removes up to 85% of coarse dust. Export-ready for compressor parts distributors and OEM procurement.

Contact Sales WhatsApp
  • Export packaging & documentation support
  • OEM / ODM customization available
  • Sample and bulk order workflow

Product Overview

49164395 is the intake air filter element used on Ingersoll Rand screw air compressors equipped with the Donaldson FPG10 air cleaner assembly. It is supplied as the primary element within a two-stage RadialSeal filtration system.

The structural difference from a conventional single-stage element is worth stating first. Air enters through a built-in tangential pre-cleaner, where the tangential inlet spins the airflow at high speed and centrifugal force throws coarse particles against the housing wall. Roughly 85% of coarse dust is separated before it reaches the main element and is discharged automatically through the Vacuator dust valve at the bottom of the housing. Pre-cleaned air then passes into the main element, where cellulose filter media performs fine filtration. This architecture matters most on dusty sites: the main element carries only the fine-particle load and maintains a longer service life in high-dust environments.

Sealing also differs from traditional elements. FPG uses Donaldson RadialSeal technology: a one-piece molded polyurethane end cap forms a radial seal directly against the housing outlet tube, eliminating the glued gasket used on older axial elements. Fewer parts means fewer failure points, and the gasket aging, detachment and misalignment problems common to older designs do not exist in the FPG structure. No tools are required for installation or removal.

Key Specifications at a Glance

ItemValue
Part number49164395
Product nameAir Filter Element
BrandIngersoll Rand
Specification basisDonaldson FPG10 (two-stage RadialSeal)
Role in assemblyPrimary element
Dimensions208 mm OD x 106 mm ID x 409 mm length
SealingRadialSeal (polyurethane end cap, no gasket)
Net weightApprox. 1.88 kg
Filtration efficiency99.9% (ISO 5011)
Pre-cleaner efficiencyUp to 85% coarse dust removal
Rated intake flowUp to 346 cfm / 9.8 m3/min
Recommended change interval2000 hours or 3 months

Technical Parameters

Filtration Performance

ParameterValue / Notes
Filtration rating5 micron class (main element)
Filtration efficiency99.9% (tested to ISO 5011)
Pre-cleaner efficiencyUp to 85% coarse dust removal (tangential stage)
Filter classTwo-stage: centrifugal pre-cleaner plus cellulose main element; HVAC filter classification (EN 779) does not apply
Dust holding capacityApprox. 1200 g

What the two-stage design changes in practice: a single-stage element forces the filter paper to handle both coarse and fine particles, so coarse dust builds quickly on the surface, pressure drop rises fast and service life is short. By shifting the coarse-dust load to the centrifugal pre-cleaner, FPG10 substantially improves the load profile on the main element. This is why the design is widely used on construction machinery, generator sets and other dust-exposed equipment.

Flow and Pressure Drop

ParameterValue / Notes
Rated air flowUp to 346 cfm / 9.8 m3/min (air cleaner assembly rating)
Filtration face velocityApprox. 0.038 m/s
Initial pressure dropApprox. 0.5-1.0 kPa (approx. 50-100 mmH2O)
Operating differential rangeFrom new-element initial resistance to blockage alarm value
Alarm / final resistancePer the machine restriction indicator yellow/red zone
Pressure drop vs. energyEach 1 kPa rise in intake resistance increases machine energy consumption by approximately 1%

Pressure drop and energy consumption

Rising intake resistance lowers intake pressure and air density. To hold the set discharge pressure and flow, the machine must do more work and specific power rises. Calculated on a theoretical compression-ratio basis at 0.7 MPa discharge pressure and 101.3 kPa atmospheric pressure:

Intake resistanceCompression ratioRelative energy increase vs. baseline
0 kPa (new element)7.91Baseline
2 kPa8.07+2.0%
4 kPa8.24+4.1%
6 kPa8.41+6.3%

Engineering implication: as an element moves from new to heavily blocked (0 to 6 kPa), machine energy consumption rises by roughly 6% over the interval. The cumulative electricity cost usually far exceeds the price of one element. This is why the original FPG10 housing provides an intake restriction indicator port: change timing is set by actual resistance rather than by calendar estimate.

Dimensions and Installation

ParameterValue / Notes
Dimensions208 mm OD x 106 mm ID x 409 mm length
ConstructionPleated cylindrical element, two-stage RadialSeal primary element
Effective filtration areaApprox. 4.3 m2
Pleat countApprox. 103 pleats
Pleat spacingApprox. 4.8 mm
Mounting interfaceRadial push-in; end cap seals against housing outlet tube
SealingRadialSeal - one-piece molded polyurethane end cap forms the radial seal; no separate gasket
Companion elementSafety element, mounted inside the primary element as backup protection

Procurement note: when cross-checking a replacement, verify all three dimensions - 208 mm OD, 106 mm ID, 409 mm length. The FPG design seals radially; push the element in until the end cap contacts the outlet tube. No additional gasket is required. Do not attempt to add a gasket - it will break the radial seal fit.

Material Composition

ParameterValue / Notes
Filter mediaCellulose filter paper, to FPG10 specification
Media basis weightApprox. 130 g/m2
Inner and outer supportGalvanized steel perforated cage (inner cage plus outer screen)
End capOne-piece molded polyurethane (PU) end cap, encapsulating both the media ends and the sealing surface
SealRadialSeal formed by the polyurethane end cap itself; no separate O-ring or gasket
BondingMolded integrally with the end cap; no additional adhesive layer

Structural note: a conventional axial element consists of a metal end cap, a glued gasket and a separate seal ring. Aging at any one of these points causes bypass. FPG encapsulates the end cap, sealing surface and media ends in a single polyurethane body, reducing part count and improving seal reliability. This is also what makes tool-free servicing possible.

Operating Condition Tolerance

ParameterValue / Notes
Operating temperatureContinuous 83 deg C
Relative humidityUp to 80% RH, no condensation
Burst strengthFilter paper burst strength approx. 200-400 kPa (per ISO 2758 paper burst test)
Collapse resistanceElement withstands intake alarm differential without collapse (RadialSeal structure supports layer by layer)
Special featuresTwo-stage filtration (built-in tangential pre-cleaner) plus Vacuator automatic dust valve
Housing characteristicsFPG housing is injection-molded plastic: corrosion-resistant and vibration-tolerant

Service Life and Maintenance

ParameterValue / Notes
Service life2000 hours or 3 months, whichever comes first
High-dust environmentsFollow the intake restriction indicator; schedule replacement once resistance enters the yellow zone
Storage shelf lifeApprox. 2-3 years (unopened, dry and ventilated conditions)

Standards

ItemDetails
Applicable product standardISO 5011 (inlet air cleaning equipment for internal combustion engines and compressors - performance testing); efficiency figures are measured to this standard
Structural standardDonaldson FPG / FRG series air cleaner specification (RadialSeal sealing system)
Commonly cited test standardsISO 2941 / 2942 / 2943 / 3723 / 3724 / 3968
Standard applicability noteThe ISO 29xx / 37xx series above are general test methods for hydraulic fluid power filter elements. If a supplier can only provide hydraulic element standards, request ISO 5011 or the original specification sheet as a supplement.

Standard Maintenance and Installation Steps

A key feature of the FPG design is tool-free maintenance, with a single service job taking about 15 minutes.

  1. Shut down, confirm zero pressure, lock out/tag out
    Stop the machine, isolate the main power and apply lockout/tagout. Criterion: controller shows system pressure at 0.

  2. Open the FPG air cleaner service cover
    Release the service cover latches - the FPG design uses two spring latches or a twist-off cover and requires no tools. Criterion: latches not broken, cover not deformed.

  3. Remove the old element
    Grip the polyurethane end cap and pull straight out. Criterion: note that the RadialSeal design has no gasket to peel off. If a residual gasket is found on the housing outlet tube, a non-original part was previously fitted and must be cleaned away.

  4. Inspect the Vacuator dust valve
    Check the Vacuator valve (rubber duckbill) at the bottom of the housing. Criterion: the valve must open and close freely, with no caked dust and no obstruction. This is the step most often skipped in FPG maintenance and the one with the most serious consequences - a blocked dust valve disables the pre-cleaner stage, shifting the full dust load onto the main element and sharply shortening its life.

  5. Check the pre-cleaner stage and dust traces inside the housing
    Look for dust bypass tracks inside the housing and abnormal accumulation in the pre-cleaner swirl zone. Criterion: no dust tracks on the inner wall; if tracks are present, inspect the sealing surfaces.

  6. Install the new element
    Push 49164395 into the housing until the polyurethane end cap contacts the outlet tube. Criterion: end cap seated against the outlet tube; no gasket is needed or permitted.

  7. Refit the service cover and check the restriction indicator
    Refit the cover and secure the latches. Confirm the intake restriction indicator reads in the green zone; if resettable, press to reset and confirm it returns correctly. Criterion: green-zone reading and correct indicator movement.

  8. Start up and record
    Start the machine, run to operating temperature and read intake restriction. Criterion: resistance within the new-element baseline range; record date, running hours and resistance reading.

Installation rule: do not start the machine before the element is seated. If the RadialSeal element is not pushed fully home, air bypasses directly through the gap between end cap and outlet tube; both the pre-cleaner and the main element then become ineffective, equivalent to running with no element at all.

Frequently Asked Questions

What specification is 49164395?
A two-stage RadialSeal primary element manufactured to Donaldson FPG10 specification. The built-in tangential pre-cleaner removes roughly 85% of coarse dust first, and the main element handles fine filtration.

Is it interchangeable with 49101637?
No. 49101637 is FPG09, with different dimensions and rated flow from FPG10. Confirmation is straightforward: read the specification marking on the end cap of the element currently fitted. If it reads FPG10, order this part; if it reads FPG09, order 49101637.

Why does this element have no gasket?
Because it uses RadialSeal radial sealing. The polyurethane end cap itself seals directly against the housing outlet tube, so no glued gasket or separate seal ring is required. Fewer parts, fewer failure points, and less chance of incorrect installation.

What does the Vacuator dust valve do?
It is the dust discharge port of the pre-cleaner stage. Coarse dust separated by the swirling airflow falls by gravity to the bottom of the housing and is discharged automatically through the Vacuator valve. Once the valve blocks, the pre-cleaner stage fails completely and all dust is pushed straight onto the main element. Check it at every element change - this is the critical maintenance action for the FPG design.

How often should it be replaced?
The recommended interval is 2000 hours or 3 months, whichever comes first. A more accurate approach is to follow the intake restriction indicator: schedule replacement once resistance enters the yellow zone. On high-dust sites, replace earlier based on the indicator reading.

Can the element be blown clean and reused?
No. This is a dry, single-use element. It must not be washed or reverse-blown with compressed air - reverse blowing damages the filter media structure and creates invisible channels that let unfiltered air pass straight through, which is more dangerous than not changing the element at all.

Can a gasket be added to improve sealing?
No, and it is unnecessary. RadialSeal seals by radial compression of the end cap body. Adding a gasket lifts the element away from the outlet tube and actually breaks the seal fit, causing bypass.

Is it normal for the intake restriction indicator never to move?
No. A stuck indicator is a common failure point and will keep giving a clean reading even when the element is actually blocked. Press and check that it returns correctly at every service; if it has failed, change the element on the conservative time interval until the indicator is repaired.

What are the pros and cons of the FPG plastic housing versus a metal housing?
The FPG injection-molded housing is corrosion-resistant, lightweight and vibration-tolerant, and will not rust in coastal salt-spray or humid environments. The tool-free servicing design also makes field maintenance faster. This is why the FPG series is widely used on construction machinery and mobile equipment.

How can I be 100% sure this is the right part?
Three steps: (1) read the specification marking on the end cap of the fitted element and confirm it is FPG10; (2) measure the old part's outer diameter and length against 208 mm and 409 mm; (3) if the old part has been discarded, provide the model marking on the air cleaner housing and we will cross-check against the FPG specification.

Compatible Equipment

This part is supplied to Donaldson FPG10 specification and fits Ingersoll Rand screw air compressors equipped with an FPG10 air cleaner.

FPG10 is a Donaldson finished air cleaner assembly specification, adopted by machine builders as a standard intake filtration unit. The decision points are as follows:

Check itemSpecification
Air cleaner specificationDonaldson FPG10 (element interchangeable with the FRG10 series)
Air cleaner rated flowUp to 346 cfm / 9.8 m3/min
Role in assemblyPrimary element
Other specification in the seriesFPG09 - part number 49101637, different dimensions and flow, not interchangeable
Sealing systemRadialSeal (polyurethane end cap radial seal)

How to confirm fit

  1. Preferred: read the specification marking on the end cap of the fitted element. If it reads FPG10, this part applies; if it reads FPG09, order 49101637.
  2. Alternative: measure the old part's outer diameter and length against 208 mm x 409 mm.
  3. Fallback: provide the model marking on the air cleaner housing or a photo of the machine nameplate, and we will cross-check against the FPG specification.

On model coverage

The Donaldson FPG10 is a universal air cleaner adopted by multiple machine builders, so the fitment range of this part is not fully equivalent to any single list of machine models. The correct basis for judgement is the fact of whether the air cleaner specification is FPG10, not the machine model itself. If the machine nameplate does not state the air cleaner specification, confirm using any one of the three methods above.

Related Components

The FPG10 air cleaner is a complete system. In addition to the primary element, seven components are serviced alongside this part. They are listed below by component, function and inspection point:

ComponentFunctionInspection point
Safety elementBackup element mounted inside the primary element; protects downstream if the primary is damaged or during change intervalsUsually replaced on the same interval as the primary or every other change; check media for damage
Vacuator dust valveAutomatic dust discharge port of the pre-cleaner stage; expels centrifugally separated coarse dust from the housingCheck at every element change: valve must open and close freely, with no caked dust and no obstruction
Restriction indicatorIndicates element blockage level; the authoritative basis for change timingCheck that the needle returns correctly; connecting line must be clear
Service cover and latchesTool-free opening structure of the FPG housingCheck latches for breakage and the cover for deformation; no air leakage once secured
FPG housing assemblyInjection-molded plastic housing with tangential inlet and pre-cleaner swirl zoneCheck inner wall for dust bypass tracks; check plastic parts for cracks
Intake hose and clampsConnect the air cleaner to the machine intake ductCheck for cracks, aging and looseness - bypass leakage is as harmful as running without an element
Other primary elements in the seriesFPG09 - part number 49101637Different dimensions and flow, not interchangeable; keep separate in stock

Companion replacement advice: the maintenance value of the FPG10 system centres on whether the pre-cleaner stage is working correctly. When changing the primary element, inspect the Vacuator valve and restriction indicator at the same time. If either small part fails, the service life of the primary element drops noticeably - their cost is far below that of the main element, yet they determine how long it lasts.